Home > Product Show

YLN-SVR-24

YLN-SVR-24 Radar Flow Rate Meter

The YLN-SVR-24 radar flow meter is a non-contact flow rate measurement device. Based on the principle of Doppler effect, by calculating the frequency difference between the electromagnetic wave of a fixed frequency emitted by the radar and the electro鈥?/p> Order Online

  • Product Principle
  • Product Features
  • Technical Parameters

The YLN-SVR-24 radar flow meter is a non-contact flow rate measurement device. Based on the principle of Doppler effect, by calculating the frequency difference between the electromagnetic wave of a fixed frequency emitted by the radar and the electromagnetic wave reflected from the surface of the fluid to be measured, the flow velocity of the fluid surface is obtained through related calculations. It can perform non-contact measurement of the fluid surface velocity of open channels, natural rivers, drainage pipe networks, etc., and it is easy to install and maintain, and simple to operate. It is widely used in hydrology, flood prevention and drainage, environmental protection and sewage monitoring and other fields, to realize 7x24 online monitoring.

The YLN-SVR-24 radar flow meter is a non-contact flow rate measurement device. Based on the principle of Doppler effect, by calculating the frequency difference between the electromagnetic wave of a fixed frequency emitted by the radar and the electromagnetic wave reflected from the surface of the fluid to be measured, the flow velocity of the fluid surface is obtained through related calculations. It can perform non-contact measurement of the fluid surface velocity of open channels, natural rivers, drainage pipe networks, etc., and it is easy to install and maintain, and simple to operate. It is widely used in hydrology, flood prevention and drainage, environmental protection and sewage monitoring and other fields, to realize 7x24 online monitoring.

S.N.

Parameters

Range

Remarks

1

Work frequency

24GHz

 

2

Flow rate measurement range

0.1锝?0m/s

Related to flow regime

3

Flow rate measurement accuracy

卤0.01m/s 锛浡?%FS

 

4

Beam angle

12掳

 

5

Installation height

0锝?5m

Related to the flow regime, recommended installation height is 锛?m

6

Vertical angle

30锝?0掳

It is recommended to be 55锝?0掳; the roll angle is recommended to be <卤2掳

7

Automatic vertical angle compensation

Accuracy 卤1掳, resolution 0.1掳

 

8

Power supply

DC6锝?0V

 

9

Power consumption

Work current锛氾紲60mA

Standby current锛氾紲35mA锛園DC12V锛堻/span>

 

10

Communication mode

RS485锛孧ODBUS protocol

Customizable protocol

11

Baud rate

9600锝?15200bps

 

12

Work temperature

-35锝?0鈩傸/span>

 

13

Temperature output

Resolution: 0.1鈩? accuracy: 卤1鈩傸/span>

 

14

Protection level

IP67

 

15

Weight

0.45kg

 

16

Size

105*105*60mm